| Sign In | Join Free | My benadorassociates.com |
|
Brand Name : Top One Power
Model Number : GI-20248
Certification : CE FCC
Place of Origin : Guangdong
MOQ : 10 pieces
Price : USD 194 ~ 202
Payment Terms : T/T
Supply Ability : 6000 pieces / month
Delivery Time : 10 work days ( According to the order quantity )
Packaging Details : carton
Rated Power : 2KW
Peak Power : 6KW
Nominal battery voltage : 12/24/48VDC
High battery protection : ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown
Output voltage : (DC battery mode) 220/230/240VAC±2%
Output frequency : (AC mains mode) automatic tracing from AC input
single phase inverter off gird dc to ac pure sinewave inverter 48v 2000w 220v with charger
Model : GI-20248
Function:
Adjustable charging current: End users can adjust AC charging current according to their own needs.
Optional battery mode: Different working mode for different battery type, which makes our converter work under best situation.
Adjustable mains priority and converter priority mode:
Mains priority: When AC mains and DC battery are connected at the same time, converter chooses AC mains for priority AC output.
| GI Series Low Frequency Pure Sine Wave Inverter (220V) | ||||||||
| Model | GI-102 | GI-152 | GI-202 | GI-302 | GI-402 | GI-502 | GI-602 | |
| Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
| Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | |
| Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC | |||||
| Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | ||||||
| AC Mains input range | 170-275VAC (220/230/240VAC)±4% | |||||||
| AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) | |||||||
| Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | ||||||
| Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | |||||||
| High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | |||||||
| High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | |||||||
| Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm | |||||||
| High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | |||||||
| Short circuit protection | Automatic shutdown | |||||||
| Output | Transfer efficiency | ≥92% | ||||||
| Output voltage | (DC battery mode) 220/230/240VAC±2% | |||||||
| Output frequency | (DC battery mode) 60/50Hz±1% | |||||||
| Output wave form | Pure sine wave | |||||||
| Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | |||||||
| AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; | |||||||
| AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | ||||||||
| The above is for output 220V system reference, 230V/240V output just multiply by percentage | ||||||||
| Output frequency | (AC mains mode) automatic tracing from AC input | |||||||
| Other | Transfer time | ≤4ms | ||||||
| Display | LCD Display with function buttons | |||||||
| Cooling system | Intelligent cooling fan control system | |||||||
| ≤42℃ slow fan, ≥45℃ fast fan | ||||||||
| AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) / | ||||||
| Deep sulphation cycle 15.5 for 4 hrs | ||||||||
| AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | |||||||
| AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages adjustable option | |||||||
| 3 Stages charging | Boost charging, direct charging, float charging | |||||||
| AC over charge protection | Battery voltage ≧16VDC (12V) ≧32VDC (24V) ≧64VDC (48V), stop charging after 60s alarm | |||||||
| Working mode (Optional) | 01 | AC mains priority | ||||||
| Always use AC mains as priority input to provide AC output and automatically charge the battery, only | ||||||||
| stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off | ||||||||
| 02 | Energy saving | |||||||
| Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on | ||||||||
| 03 | DC battery priority | |||||||
| Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts | ||||||||
| DC to AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC | ||||||||
| output and automatically start charging the battery (for 24V/48V system, multiply by 2/4 accordingly) | ||||||||
| Comnunication | RS-232/USB/SNMP(additional option) | |||||||
| Environment | Temperature | -20~75℃ | ||||||
| Humidity | <95% | |||||||
| Appearance | Product size (mm) | 430*310*270mm | 600*270*200mm | |||||
| Packing size (mm) | 540*350*300mm | 720*310*270mm | ||||||
| Net Weight (kg) | 15kg | 17kg | 24.5kg | 29kg | 44kg | 48.1kg | 49.5kg | |
| Gross Weight (kg) | 16.5kg | 19kg | 27kg | 31kg | 46kg | 50.1kg | 52.2kg | |
| *Product specifications are subject to change without further notice | ||||||||
About us:
1.Professional--Over 13 years Professional Solar inverter & UPS Power System Producing Experience.
2.Powerful productivity-- We can produce high frequency inverter 30000 pcs/ month, low frequency inverter 3500 pcs/month.
3.Hi-tech-- Powerful R&D department can provide professional technical support.
4.Certification-- Applied with CE, FCC certification.
5.Warranty--One year warranty.

Our service:
OEM service: We offer Professional OEM service. We have a comprehensive R&D team, proficient in exterior design, packaging design, programming, wiring, structural optimization, etc. We are confident to satisfy you on both hardware and software.
After-sales team: We have a specialized after-sales team to help answer question for 24 hours. When problem arises while using or need to adapt to the local grid, our after-sale engineer will follow up the issue.
Project Team: We have a specialized project engineering team aiming at the on-grid and off-grid system. If necessary, we can send the engineering team to the local for inspection and design the suitable system as well as conduct optimization and maintenance.
|
|
single phase inverter off gird dc to ac pure sinewave inverter 48v 2000w 220v with charger Images |